Hydrite Ag & Sulfur / Where it fits
Where it fits

From a spectrum in the liquor to a tag in your DCS.

Inline means the probe sits in the line or vessel and measures the medium directly. The analyzer cabinet sits near the measurement point, at a location agreed in the feasibility report, and each value reaches the control system seconds after the spectrum is taken.

01Installation points

Three candidate points at each thiosulfate plant.

One cabinet serves two points as standard, with more on request. The feasibility report recommends which two come first at each plant.

Spectrally X1 INLINE cabinet next to process pipingPoint A

Reaction outlet

The concentration leaving the reaction step, read on the clarified liquor. Where the stream carries suspended sulfur, the point moves downstream of filtration.

Liquid fertilizer storage tanks (illustrative)Point B

Storage tank recirculation

Homogeneity and final concentration of the volume that feeds load-out, read in the recirculation loop over a full turnover.

Hydrite tanker tractor at a loading rackPoint C

Load-out line

A reading on a load-out line that stays liquid-filled, stored with a time stamp for each load.

Pressure, temperature and location of each candidate point are checked in the feasibility workshop against the probe rating: up to 16 bar and −40 to +125 °C. The probe connects to the cabinet by optical fiber, on a flange, Tri-Clamp or retractable holder.
02Self-cleaning probe

The window stays clean on a timed cycle.

Thiosulfate liquors are clear, and any optical window in a process line still collects deposits over a campaign. The retractable module takes the probe out, rinses the window and returns it, on a schedule set for your line.

◉
Measure
↑
Retract
≈
Rinse
↓
Return
The window is cleaned on a retract, rinse and return cycle while the analyzer keeps its place in the line. Calibration runs automatically against a reference built into the probe.
03Into your control system

A value in the control system, with the spectrum stored beside it.

Each reading arrives as an ordinary process tag.

Modbus

Into the PLC or DCS

Thiosulfate, sulfate and homogeneity values as tags, with alarm limits set in Spectrally OS.

PASS/FAIL

Flags on the grade

Each spectrum is classified against the grade specification, and the flag goes to the same control system.

Record

A file per load

Results and raw spectra stored locally, exportable as CSV, PDF or raw data, with role-based access.

04Path to the line

From your samples to a value in the DCS in 3 to 5.5 months.

The steps are the same for every liquor; the timing for your line is set in the feasibility report.

Feasibility workshop

A working session with your technology, production and quality people: measurement points, analytes and the KPIs that matter on your line.

about 3 hours

Feasibility study

We measure 3 to 5 representative batches or samples in the Gekko lab, build the calibration models and quantify the gain as a documented scenario on your data.

about 4 weeks

Installation

Probe and cabinet on the selected line, validation against your laboratory, operator training and integration with your control system.

6 to 12 weeks

Scale-up

Further measurement points once the first one runs on its model, on the same software layer and the same service team.

3 to 5.5 months to the first running point
05What the plant provides

A short list, agreed in the feasibility report.

People for the workshopTechnology, production and quality, for about three hours
Samples3 to 5 representative batches or samples, with the lab values you already have for them
Process connectionFlange DN32/40/50 PN16, ANSI 1¼″/1½″/2″ Class 150, NPT male 1¼″ or Tri-Clamp 1½″/2″, or a custom design; retractable process holder where the probe has to come out under process conditions
Power at the cabinet230 V AC, 50/60 Hz, grounded; 300 W
Cabinet location0–45 °C ambient, 20–70% RH non-condensing
Control systemA Modbus endpoint in the PLC, DCS or SCADA, scoped with your automation and OT team
OperatorsOne training session for up to 10 people, on site or online
Point dataPressure, temperature and area classification of each candidate point
Spectrally X1 PROBE on a process pipe
Spectrally X1 PROBE installed on a process line.
Aleksandra Łukasiewicz
Aleksandra Łukasiewicz
Head of International Sales

Hope you find it interesting. Please contact us and talk about our analysis in detail.

a.lukasiewicz@gekkophotonics.com+1 804 593 0282

We care about your privacy

We use cookies to ensure the site functions properly, measure traffic, and personalize marketing only with your consent.