CASE STUDY

Control of ammonium thiosulfate (ATS) concentration in sulfur fertilizer

Ammonium thiosulfate (ATS) must meet the specification for concentration and N/S ratio, and offline measurement takes 20 to 60 minutes. We demonstrate how to control ATS concentration and solution homogeneity inline.

Industry
Production fertilizers sulfur-containing
Scope
Control of ammonium thiosulfate (ATS) concentration and N/S ratio
Magazyn ciekłych nawozów siarkowych

Client context

ATS (ammonium thiosulfate, approximately 12% nitrogen and 26% sulfur) is a sulfur fertilizer and nitrification inhibitor, produced by absorption of gases and used as an additive to UAN or applied directly to sulfur-deficient soils.

ATS concentration and N/S ratio must meet specification; deviations lead to customer complaints and issues with CE certification. The line produces a continuous stream, and offline composition measurement takes 20 to 60 minutes.

Challenge.

  • Iodometric titration of thiosulfate takes 20–30 minutes; full anion analysis by ion chromatography takes 30–60 minutes.
  • The absorption process produces a continuous stream, so offline measurement is too slow for real-time control.
  • Deviations in N/S ratio result in complaints and risk during CE certification (EU Regulation 2019/1009).
  • Densitometry provides only an approximate concentration reading, without qualitative composition data.

Solution

Spectrally™ X1 measures ammonium thiosulfate concentration and solution homogeneity inline, in the absorption process stream. It provides real-time composition control instead of spot-check laboratory sampling.

Raman is well suited for this measurement because the thiosulfate ion has strong, characteristic vibrational bands of sulfur bonds (S-O and S-S), clearly distinguishable from sulfates and other anions present in the solution. Water gives a weak signal and does not overwhelm the analyte, so composition can be tracked directly in the stream without sample preparation.

Results

MetricResult
What we measure in-lineammonium thiosulfate concentration and solution homogeneity (indirectly the N/S ratio)
Timein-stream control instead of 20–30 min iodometric titration
ComplianceEU Regulation 2019/1009 (CE marking) – composition documentation

What this means for your process

If you produce ATS or UAN blends with sulfur addition, inline measurement allows you to maintain concentration and N/S ratio within specification without waiting for the laboratory, reducing complaints and certification risk.

The most reliable way to confirm performance on your stream is a short feasibility study on real samples.

Contact Us

Find out how much you can save on your process with Spectrally™.

Contact

Aleksandra Łukasiewicz

If you are facing a similar challenge in chemical process control, quality stabilization, or real-time reaction monitoring, let's discuss a solution tailored to your technological conditions.

We care about your privacy