Spectrally™ puts an immersion Raman probe straight into your PDMS, addition-cure LSR/HCR, chlorosilane and medical-grade silicone lines. Siloxane chain length, silanol and vinyl content, residual cyclics and cure state - read inline, directly in the reactor rather than pulled to a lab, in seconds and with no sampling or reagents.
< 5 s to a process value0 sampling · 0 reagents24/7 self-cleaning probeAutomatic calibration
Silicone condensation and addition cure, the chlorosilane monomers upstream, and medical-grade LSR and RTV for Class III devices.
Master variable
Chain length & crosslinking
Siloxane chain length, Si-H and vinyl crosslinking and residual cyclics - the properties that set every silicone grade, read live instead of after the batch.
Reference technique
Raman spectroscopy
The core of the Spectrally platform - it reads the diagnostic silicone bands directly, around 70% of the measurement portfolio.
Where it sits
In the reactor, 24/7
Immersion probe in the reactor or line, feeding your PLC / DCS continuously.
01Inside this mini-site
Everything a silicone plant asks us - one page per answer.
Six focused pages: the chemistries we cover, the parameters we read, how the measurement works, the proof behind it, the regulatory context and the instrument itself.
Residual cyclics come back from GC/MS 60 to 120 minutes later; cure state waits on gel-time or a 30 to 90 minute DSC run. By then the reactor has moved on, and the specialised chemistry has queued behind a specialised lab.
Offline lab loop
60-120min
Sample, extract, run GC/MS for residual cyclics or DSC for cure state, wait, report. Inline viscometry gives a molecular-weight proxy but no composition, and NIR cannot separate cyclic from linear siloxane. The result describes a reactor state that has already passed.
Spectrally inline
< 5s
The immersion probe reads the Si-H, vinyl and siloxane bands in the reactor continuously and streams values to your control system. Cure state and residual cyclics are caught while you can still act - so GC/MS and DSC become verification, not the bottleneck.
Measurement
0s
Spectrum to a process value, continuously.
Sensitivity
0ppm
Single-ppm composition sensitivity where the chemistry demands it.
System CAPEX
0k
One-time system cost in EUR, 75-250k by configuration.
Deployment
0mo
From feasibility to a validated model on your line.
Your next step
Put it on your silicone line - starting with your own stream.
Send representative samples or process data from your PDMS, LSR/HCR, chlorosilane or medical-grade silicone stream. We build and validate a chemometric model on your matrix and hand you the numbers inline Raman reads on your line - siloxane chain length, cure state and residual cyclics - benchmarked against your GC/MS and DSC reference methods.