Inline Raman · Industrial & specialty silicones

Read the chemistry that defines the silicone.

Spectrally™ puts an immersion Raman probe straight into your PDMS, addition-cure LSR/HCR, chlorosilane and medical-grade silicone lines. Siloxane chain length, silanol and vinyl content, residual cyclics and cure state - read inline, directly in the reactor rather than pulled to a lab, in seconds and with no sampling or reagents.

< 5 s to a process value 0 sampling · 0 reagents 24/7 self-cleaning probe Automatic calibration
Chemistry
PDMS · LSR/HCR · Chlorosilane · Medical-grade

Silicone condensation and addition cure, the chlorosilane monomers upstream, and medical-grade LSR and RTV for Class III devices.

Master variable
Chain length & crosslinking

Siloxane chain length, Si-H and vinyl crosslinking and residual cyclics - the properties that set every silicone grade, read live instead of after the batch.

Reference technique
Raman spectroscopy

The core of the Spectrally platform - it reads the diagnostic silicone bands directly, around 70% of the measurement portfolio.

Where it sits
In the reactor, 24/7

Immersion probe in the reactor or line, feeding your PLC / DCS continuously.

02 The gap you know too well

Characterisation that lags the batch.

Residual cyclics come back from GC/MS 60 to 120 minutes later; cure state waits on gel-time or a 30 to 90 minute DSC run. By then the reactor has moved on, and the specialised chemistry has queued behind a specialised lab.

Offline lab loop
60-120min

Sample, extract, run GC/MS for residual cyclics or DSC for cure state, wait, report. Inline viscometry gives a molecular-weight proxy but no composition, and NIR cannot separate cyclic from linear siloxane. The result describes a reactor state that has already passed.

Spectrally inline
< 5s

The immersion probe reads the Si-H, vinyl and siloxane bands in the reactor continuously and streams values to your control system. Cure state and residual cyclics are caught while you can still act - so GC/MS and DSC become verification, not the bottleneck.

Measurement
0s

Spectrum to a process value, continuously.

Sensitivity
0ppm

Single-ppm composition sensitivity where the chemistry demands it.

System CAPEX
0k

One-time system cost in EUR, 75-250k by configuration.

Deployment
0mo

From feasibility to a validated model on your line.

Your next step

Put it on your silicone line - starting with your own stream.

Send representative samples or process data from your PDMS, LSR/HCR, chlorosilane or medical-grade silicone stream. We build and validate a chemometric model on your matrix and hand you the numbers inline Raman reads on your line - siloxane chain length, cure state and residual cyclics - benchmarked against your GC/MS and DSC reference methods.

What would you like to do?

Explore Spectrally X1 INLINE →