Spectrally™ puts a Raman probe straight into your ATS, KTS/CaTS and AMS stream - inline, meaning in the absorption stream, pipeline or tank itself, with no sampling. Thiosulfate concentration, the N/S ratio and solution homogeneity - measured in seconds, continuously, with no reagents, instead of waiting 20 to 60 minutes on iodometric titration or ion chromatography.
< 5 s to a process value0 sampling · 0 reagents24/7 continuous measurementAutomatic calibration
Ammonium, potassium and calcium thiosulfate plus ammonium sulfate - the aqueous sulfur-fertilizer streams produced by gas absorption.
Master variable
Thiosulfate concentration & N/S ratio
The numbers that define the product - read live instead of inferred after the batch.
Reference technique
Raman spectroscopy
Thiosulfate and sulfate are strong Raman-active oxyanions, and water is a weak Raman scatterer - so Raman reads them cleanly inline.
Where it sits
In the absorption stream, 24/7
Immersion probe in the absorption stream, pipeline or tank, feeding your PLC / DCS continuously.
01Inside this mini-site
Everything a sulfur-fertilizer plant asks us - one page per answer.
Six focused pages: the chemistries we cover, the parameters we read, how the measurement works, the technical case behind it, the regulatory context and the instrument itself.
Iodometric thiosulfate titration answers in 20 to 30 minutes; full anion analysis by ion chromatography takes 30 to 60; densitometry is only a concentration proxy and never sees composition. The absorption process runs continuously, so by the time the result is back the stream has moved on.
Offline lab loop
20-60min
Sample, walk to the lab, run iodometric titration or ion chromatography, wait, report. A thiosulfate-concentration or N/S-ratio deviation only surfaces as an off-spec delivery at your customer - after the product has shipped, where it becomes a complaint and a CE-certification problem.
Spectrally inline
< 5s
The probe reads the absorption stream, pipeline or tank continuously and streams thiosulfate concentration, N/S ratio and homogeneity to your control system. The deviation is caught while you can still correct it - so titration and ion chromatography become verification, not the bottleneck.
Measurement
0s
Spectrum to a process value, continuously.
Resolution
0ppm
Composition resolved down to single ppm.
Typical CAPEX
0
System CAPEX 75 to 250k EUR - no reagents, no consumables.
Deployment
0mo
Typical from feasibility to line, 3 to 5.5 months.
Your next step
Put it on your stream - starting with your own samples.
Send representative samples or process data from your ATS, KTS/CaTS or AMS stream. We build and validate a chemometric model on your matrix and show you exactly what inline Raman would read on your line - before any commitment. Your feasibility study puts the numbers on the table: the validated model and the figures for your own material.